SHIELDED PAIRED CABLES 


MULTIPLE PAIRED SHIELDED CABLES--ALUMINUM MYLAR FOIL SHIELD
 
 

DESCRIPTION:  22 AWG 7/30 T.C.  conductors in each pair, .010" Polypropylene insulation,  each pair
twisted
with a 24(7) T.C. drain wire, then an Aluminum Mylar foil shield, foil in.   The shielded pairs
are cabled, chrome
PVC jacket overall.  Color coded.  100% shielding coverage.   Jacket  passes UL
VW-1 vertical wire flame test.
Suitable for audio, pulse, data, & RF applications requiring superior
circuit isolation.  Polypropylene is used
for it's mechaincal toughness & high frequency properties.     
OPER. TEMP.: -55°C to +105°C.
OPER. VOLT.: 300V.   See color code for paired cables. 
Nom. Capacitance between conductors connected to shield: 28pF/ft.  
Nom. Capacitance between one conductor and remaining conductor connected to shield: 57pF/ft.
Can be run to order as UL 2493 Ty.CM, CSA PCC FT4 300V.

STD. P-U: 500’, 1000’

 

BRIM
No.
  No.
Pairs
  No.
Cond.
AWG Strand. Nom.
Wall
Nom.
Jack.
Nom.
O.D.
1638/3      3     6   22    7/30 .010" .025" .255"
1638/6      6    12   22    7/30 .010" .030" .345"
1638/9      9    18   22    7/30 .010" .035" .410"
1638/11    11    22   22    7/30  .010" .040" .460"
1638/15    15    30   22    7/30 .010" .045" .535"
1638/19    19    38   22    7/30 .010" .050" .575"
1638/27    27    54   22    7/30 .010" .055" .690"

RoHS compliant constructions are available to order.
OTHER CONSTRUCTIONS AVAILABLE TO ORDER. 



MULTIPLE PAIRED SHIELDED CABLES--ALUMINUM MYLAR FOIL SHIELD--
22AWG & 18AWG
 
 

DESCRIPTION:  Conductors in each pair are composed of 22 AWG 7/30 T.C., .010" Polyethylene, or 18
AWG
16/30 T.C., . 016" wall of Polyethylene insulation,  each pair twisted with a 24(7) or 20(7) TC
drain wire, then an
Aluminum Mylar foil shield, foil in.  The shielded pairs are cabled, chrome PVC
jacket overall.    Color coded.
100% shielding coverage.  Suitable for audio, pulse, data, and RF
applications requiring superior circuit isolation.
OPER. VOLT.: 300V.   OPER. TEMP.: -20°C to +80°C.  
Nom. Capacitance between conductors connected to shield: 25pF/ft. 
Nom. Capacitance between one conductor & remaining conductor connected to shield: 45pF/ft. 
See color code for paired cables.              STD. P-U: 500’, 1000’

                             22 AWG 7/30  

BRIM
No.
  No.
Pairs
  No.
Cond.
AWG Strand. Nom.
Wall
Nom.
Jack.
Nom.
O.D.
1630/3      3     6   22    7/30 .010" .025" .255"
1630/6      6    12   22    7/30 .010" .030" .345"
1630/9      9    18   22    7/30 .010" .035" .410"
1630/11    11    22   22    7/30  .010" .040" .460"
1630/15    15    30   22    7/30 .010" .045" .535"
1630/19    19    38   22    7/30 .010" .050" .575"
1630/27    27    54   22    7/30 .010" .055" .690"

                             18 AWG 16/30  

BRIM
No.
  No.
Pairs
  No.
Cond.
AWG Strand. Nom.
Wall
Nom.
Jack.
Nom.
O.D.
1632/3      3     6   18  16/30 .016" .035" .375"
1632/6      6    12   18  16/30 .016" .045" .555"
1632/9      9    18   18  16/30 .016" .055" .620"
1632/11    11    22   18  16/30  .016" .060" .745"
1632/15    15    30   18  16/30 .016" .065" .820"
1632/19    19    38   18  16/30 .016" .075" .870"
1632/27    27    54   18  16/30 .016" .085" .995"

RoHS compliant constructions are available to order.



MULTIPLE PAIRED SHIELDED CABLES--ALUMINUM MYLAR FOIL SHIELD--

22AWG  SOLID CONDUCTORS
 
 

DESCRIPTION:  Conductors in each pair are composed of 22 AWG (1) TC, .013" PVC insulation,  each
pair twisted
with a 24(1) TC drain wire, then an Aluminum Mylar foil shield, foil in.  The shielded pairs
are cabled, chrome PVC
jacket overall.  Color coded.  100% shielding coverage.  Suitable for audio,
pulse,  data, & RF applications requiring
superior circuit isolation.    OPER. TEMP.: -20°C to +80°C.
Nom. Capacitance
between conductors connected to shield: 43pF/ft.   
Nom. Capacitance between one conductor and
remaining conductor connected to shield: 82pF/ft.   
OPER. VOLT
.: 300V.    See color code for paired cables.

STD. P-U: 500’, 1000’  

BRIM
No.
  No.
Pairs
  No.
Cond.
AWG Strand. Nom.
Wall
Nom.
Jack.
Nom.
O.D.
1635/3      3     6   22     1 .013" .035" .275"
1635/6      6    12   22     1 .013" .037" .395"
1635/9      9    18   22     1 .013" .040" .440"
1635/11    11    22   22     1  .013" .040" .485"
1635/15    15    30   22     1 .013" .045" .540"
1635/19    19    38   22     1 .013" .055" .660"
1635/27    27    54   22     1 .013" .070" .800"

RoHS compliant constructions are available to order.
CONSTRUCTION VARIATIONS TO ORDER. 


ALUMINUM MYLAR FOIL SHIELDED COMMUNICATION CABLE
 

DESCRIPTION:  22 AWG solid tinned copper conductors,  .008" wall of  Polypropylene insulation, 
or a .010"
wall of  PVC, color coded conductors twisted into pairs, an Aluminum mylar foil shield
overall, foil out, a stranded T.C. drain wire, chrome PVC jacket overall.  100% shielding coverage.  
Drain wire provides quick and
easy grounding.   Polypropylene insulation is used because of it's
mechanical toughness and excellent high
frequency properties.  Suitable for communicatoion,
telephone and sound systems, control and instrumentation
cable. 
OPER. VOLT.: 200V.   OPER. TEMP.: -40°C to +105°C.

See color code for paired cables.  STD. P-U: 500',1000'  

BRIM
No.
  No.
Pairs
AWG/
Stand.
Insul.
Type
Nom.
Wall
Nom.
Jack.
Nom.
O.D.
1633/38    38   22-1   PP .008" .045" .575"
1633/51    51   22-1  PVC .010" .050" .686"

CONTRUCTION VARIATIONS ARE AVAILABLE TO ORDER.
RoHS compliant constructions are available to order.



    UL SHIELDED COMPUTER AND CONTROL CABLES

DESCRIPTION:  Each conductor UL Type 1061, 24 AWG 7/32 T.C., UL VW-1.  Conductors are paired,
cabled,
mylar wrap, braided tinned copper shield, chrome PVC jacket overall.  Color coded.  Shielding
coverage a minimum of  85%.  Cable meets UL Styles 2343 and  2344.   Suitable as a control cable,
computer cable,  shielded
audio cable.  OPER. VOLT.: 300V UL    OPER. TEMP.: -40°C to +80°C.
See color code for paired cables.               STD. P-U: 500’, 1000’  

BRIM No. No. Pairs AWG Strand. Nom. Wall Nom. Jack. Nom. O.D.
1886/5        5   24    7/32     .009"     .062"     .355"
1886/7        7   24    7/32     .009"     .062"     .375"
1886/12       12   24    7/32     .009"     .062"     .460"
1886/15       15   24    7/32      .009"     .062"     .510"
1886/19       19   24    7/32     .009"     .062"     .530"
1886/27       27   24    7/32     .009"     .062"     .620"
1886/37       37   24    7/32     .009"     .062"     .690"
1886/48       48   24    7/32     .009"     .062"     .775"
1886/60       60   24    7/32     .009"     .062"     .845"

RoHS compliant constructions are available to order.
CONTRUCTION VARIATIONS ARE AVAILABLE TO ORDER.



BRIM ELECTRONICS, INC. 120 HOME PLACE    LODI, NJ 07644
TEL: 201-796-2886     FAX: 973-778-2792     E-MAIL: info@brimelectronics.com