BRIM
PVC HOOK-UP WIRE -- MIL SPEC -
UL
- BRIMFLYXTM -
TEST LEAD WIRES
DESCRIPTION: Very
flexible soft bare copper stranded conductor, insulated with
a special flexible PVC
formulation to minimize
kinking and allow for ultra-low bending torque.
Designed for use where wires
encounter continuous
flexing, such as in data processing equipment, mercury
thermostats, magnetic
drums, and rotating servo
platforms. OPER. TEMP.: -40°C to
+80°C.
STD.
P-U: 1000'
Brimflyx™ No. |
AWG | Strand. | Nom. Wall |
Max. Volt. |
Nom. O. D. |
Brimflyx™ No. |
AWG | Strand. | Nom. Wall |
Max. Volt. |
Nom. O. D. |
|
1250/38 | 38 | 7/46 | .005" | 200 | .015" | 1250/24 | 24 | 105/44 | .010" | 600 | .049" | |
1250/36 | 36 | 7/44 | .005" | 200 | .016" | 1251/24 | 24 | 105/44 | .015" | 1000 | .059" | |
1250/34 | 34 | 10/44 | .005" | 200 | .018" | 1250/22 | 22 | 168/44 | .010" | 600 | .054" | |
1250/32 | 32 | 18/44 | .007" | 300 | .023" | 1251/22 | 22 | 168/44 | .015" | 1000 | .064" | |
1250/30 | 30 | 28/44 | .010" | 600 | .031" | 1250/20 | 20 | 259/44 | .010" | 600 | .061" | |
1250/29 | 29 | 51/46 | .010" | 600 | .032" | 1250/18 | 18 | 413/44 | .010" | 600 | .072" | |
1250/28 | 28 | 41/44 | .010" | 600 | .035" | 1251/18 | 18 | 413/44 | .015" | 1000 | .082" | |
1250/27 | 27 | 48/44 | .010" | 600 | .037" | 1250/16 | 16 | 665/44 | .010" | 600 | .087" | |
1250/26 | 26 | 66/44 | .010" | 600 | .042" | 1251/14 | 14 | 1050/44 | .015" | 1000 | .115" |
RoHS COMPLIANT RESINS ARE AVAILABLE TO ORDER.
DESCRIPTION:
Stranded tinned copper conductor, .032" soft, smooth, shiny
very flexible PVC insul-
ation. Suitable as a
test lead wire, power, grounding, or portable lead
wire. The special soft form-
ulation vinyl gives maximum
flexibility, plus high & low temperature capability,
with a high voltage
rating.
Resistant to oils and gasoline. has excellent abrasion
resistance. Kinkless.
OPER. VOLT.: 5000
Volts. OPER. TEMP.:-55°C to +105°C. STD. P-U:
100,1000'
Brim No. |
AWG | Strand. | Amps | Nom. Wall |
Nom. O. D. |
1870/22 | 22 | 26/36 | 1 | .032" | .092" |
1870/20 | 20 | 26/34 | 3 | .032" | .100" |
1870/18 | 18 | 65/36 | 7 | .032" | .112" |
1870/16 | 16 | 65/34 | 10 | .032" | .125" |
STD.COLORS: Black, Red,
White, Blue, Green. OTHER COLORS AVAILABLE
TO ORDER.
OTHER CONSTRUCTIONS ARE
AVAILABLE TO ORDER. RoHS compliant.
MIL-W-16878/1,/2,/3,/17,/18,/19
DESCRIPTION:
Stranded tinned copper conductor with a flame, fungus, oil,
acid, solvent, alkali &
moisture resistant PVC
insulation or PVC with a Nylon jacket insulation rated for
-55°C to +105°C.
STD. Colors: Black, Blue,
Brown, Gray, Green, Orange, Red, Violet, White, Yellow.
TYPE
B--uncovered OPER. VOLT.:
600V OPER. TEMP: -55°C to +105°C
Description: 7str. or
19str. tinned copper, .010" wall 105°C PVC. STD.
P-U: 100',1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
|
1405/32 | B-32 | 32-7/40 | .010" | 600 | .028" | 1406/22 | B-22 | 19/34 | .010" | 600 | .050" | |
1405/30 | B-30 | 30-7/38 | .010" | 600 | .031" | 1405/20 | B-20 | 7/28 | .010" | 600 | .057" | |
1405/28 | B-28 | 28-7/36 | .010" | 600 | .034" | 1406/20 | B-20 | 19/32 | .010" | 600 | .058" | |
1405/26 | B-26 | 26-7/34 | .010" | 600 | .038" | 1405/18 | B-18 | 7/26 | .010" | 600 | .067" | |
1405/24 | B-24 | 24-7/32 | .010" | 600 | .043" | 1406/18 | B-18 | 19/30 | .010" | 600 | .068" | |
1406/24 | B-24 | 24-19/36 | .010" | 600 | .044" | 1406/16 | B-16 | 19/29 | .010" | 600 | .077" | |
1405/22 | B-22 | 22-7/30 | .010" | 600 | .049" | 1406/14 | B-14 | 19/27 | .010" | 600 | .091" |
RoHS compliant wires are available to order.
TYPE
C--uncovered OPER. VOLT.:
1000V OPER. TEMP: -55°C to
+105°C
Description: 7str. or
19str. tinned copper, .016" wall 105°C PVC. STD.
P-U: 100',1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
1410/24 | C-24 | 24-7/32 | .016" | 1000 | .058" |
1410/22 | C-22 | 22-7/30 | .016" | 1000 | .064" |
1410/20 | C-20 | 20-7/28 | .016" | 1000 | .072" |
1410/18 | C-18 | 18-7/26 | .016" | 1000 | .082" |
1410/16 | C-16 | 16-19/29 | .016" | 1000 | .091" |
1410/14 | C-14 | 14-19/27 | .016" | 1000 | .105" |
1410/12 | C-12 | 12-19/25 | .016" | 1000 | .124" |
RoHS compliant wires are available to order.
TYPE
D--uncovered OPER. VOLT.:
3000V OPER. TEMP: -55°C to +105°C
Description: Stranded
tinned copper conductor, .030" to .045" wall 105°C
PVC. STD. P-U: 100',1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
|
1415/24 | D-24 | 24-7/32 | .030" | 3000 | .083" | 1415/12 | D-12 | 65/30 | .035" | 3000 | .176" | |
1415/22 | D-22 | 22-7/30 | .030" | 3000 | .089" | 1415/10 | D-10 | 105/30 | .035" | 3000 | .200" | |
1415/20 | D-20 | 20-7/28 | .030" | 3000 | .097" | 1415/8 | D-8 | 133/29 | .040" | 3000 | .247" | |
1415/18 | D-18 | 18-16/30 | .030" | 3000 | .110" | 1415/6 | D-6 | 133/27 | .040" | 3000 | .291" | |
1415/16 | D-16 | 16-26/30 | .030" | 3000 | .122" | 1415/4 | D-4 | 133/25 | .045" | 3000 | .356" | |
1415/14 | D-14 | 14-41/30 | .030" | 3000 | .140" | 1415/2 | D-2 | 665/30 | .045" | 3000 | .425" |
RoHS compliant wires are available to order.
TYPE BN--Nylon
covered OPER. VOLT.:
600V OPER. TEMP: -55°C to +105°C
Description: 7str. or
19str. tinned copper, .010" wall 105°C PVC plus .002" to
.004" NYLON jacket.
STD. P-U: 100',1000'
Brim No. |
MIL/ Type |
AWG/ Strand. |
Nom. Wall |
Nylon Jack. |
Oper. Volt. |
Nom. O. D. |
Brim No. |
MIL/ Type |
AWG/ Strand. |
Nom. Wall |
Nylon Jack. |
Oper. Volt. |
Nom. O. D. |
|
1405/32N | BN-32 | 32- 7/40 | .010" | .002" | 600 | .032" | 1406/22N | BN-22 | 22-19/34 | .010" | .003" | 600 | .056" | |
1405/30N | BN-30 | 30- 7/38 | .010" | .002" | 600 | .035" | 1405/20N | BN-20 | 20- 7/28 | .010" | .003" | 600 | .063" | |
1405/28N | BN-28 | 28- 7/36 | .010" | .002" | 600 | .038" | 1406/20N | BN-20 | 20-19/32 | .010" | .003" | 600 | .064" | |
1405/26N | BN-26 | 26- 7/34 | .010" | .003" | 600 | .044" | 1405/18N | BN-18 | 18- 7/26 | .010" | .003" | 600 | .073" | |
1405/24N | BN-24 | 24- 7/32 | .010" | .003" | 600 | .049" | 1406/18N | BN-18 | 18-19/30 | .010" | .003" | 600 | .074" | |
1406/24N | BN-24 | 24-19/36 | .010" | .003" | 600 | .050" | 1406/16N | BN-16 | 16-19/29 | .010" | .003" | 600 | .083" | |
1405/22N | BN-22 | 22- 7/30 | .010" | .003" | 600 | .055" | 1406/14N | BN-14 | 14-19/27 | .010" | .004" | 600 | .099" |
RoHS compliant wires are available to order.
TYPE CN--Nylon
covered OPER. VOLT.:
1000V OPER. TEMP: -55°C to +105°C
Description: 7str. or
19str. tinned copper, .016" wall 105°C PVC plus a .002" to
.005" Nylon jacket.
STD. P-U: 100',1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Nylon Jack. |
Oper. Volt. |
Nom. O. D. |
1410/24N | CN-24 | 24-7/32 | .016" | .002" | 1000 | .062" |
1410/22N | CN-22 | 22-7/30 | .016" | .003" | 1000 | .070" |
1410/20N | CN-20 | 20-7/28 | .016" | .003" | 1000 | .078" |
1410/18N | CN-18 | 18-7/26 | .016" | .003" | 1000 | .088" |
1410/16N | CN-16 | 16-19/29 | .016" | .004" | 1000 | .099" |
1410/14N | CN-14 | 14-19/27 | .016" | .004" | 1000 | .113" |
1410/12N | CN-12 | 12-19/25 | .016" | .005" | 1000 | .134" |
RoHS compliant wires are available to order.
TYPE DN--Nylon
covered OPER. VOLT.:
3000V OPER. TEMP: -55°C to +105°C
Description: stranded
tinned copper conductor, .030" to .045" wall 105°C PVC plus
a
.004" to .008" Nylon
jacket. STD. P-U: 100',1000'
Brim No. |
MIL/ Type |
AWG/ Strand. |
Nom. Wall |
Nylon Jack. |
Oper. Volt. |
Nom. O. D. |
1415/24N | DN-24 | 24- 7/32 | .030" | .004" | 3000 | .091" |
1415/22N | DN-22 | 22- 7/30 | .030" | .004" | 3000 | .096" |
1415/20N | DN-20 | 20- 7/28 | .030" | .004" | 3000 | .105" |
1415/18N | DN-18 | 18-16/30 | .030" | .004" | 3000 | .118" |
1415/16N | DN-16 | 16-26/30 | .030" | .005" | 3000 | .132" |
1415/14N | DN-14 | 14-41/30 | .030" | .005" | 3000 | .150" |
1415/12N | DN-12 | 12-65/30 | .035" | .005" | 3000 | .186" |
1415/10N | DN-10 | 10-105/30 | .035" | .006" | 3000 | .207" |
1415/8N | DN-8 | 8-133/29 | .040" | .006" | 3000 | .263" |
1415/6N | DN-6 | 6-133/27 | .040" | .008" | 3000 | .307" |
1415/4N | DN-4 | 4-133/25 | .045" | .008" | 3000 | .374" |
RoHS compliant wires are available to order.
DESCRIPTION: Solid
or stranded tinned copper conductor with a flame, fungus,
acid, oil, solvent, alkali
and moisture resistant PVC
insulation, or PVC with a Nylon or glass braided jacket.
OPER. VOLT.: -40°C to +80°C.
STD. Colors: (0)Black,
(1)Brown, (2)Red, (3)Orange, (4)Yellow, (5)Green,
(6)Blue, (7)Violet, (8)Gray, (9)White
TYPE
LW--uncovered OPER. VOLT.:
300V OPER. TEMP: -40°C to +80°C
Description: Stranded
tinned copper, .010" wall of 80°C PVC
insulation. STD. P-U: 1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
|
1418/30 | LW-C-30(7)A | 30-7/38 | .010" | 300 | .032" | 1418/22 | LW-C-22(7)A | 7/30 | .010" | 300 | .052" | |
1418/28 | LW-C-28(7)A | 28-7/36 | .010" | 300 | .036" | 1418/20 | LW-C-20(7)A | 7/28 | .010" | 300 | .060" | |
1418/26 | LW-C-26(7)A | 26-7/34 | .010" | 300 | .040" | 1418/18 | LW-C-18(16)A | 16/30 | .010" | 300 | .070" | |
1418/24 | LW-C-24(7)A | 24-7/32 | .010" | 300 | .044" | 1418/16 | LW-C-16(19)A | 19/29 | .010" | 300 | .078" |
RoHS compliant wires are available to order.
TYPE
MW-C--uncovered OPER. VOLT.:
1000V OPER. TEMP: -40°C to +80°C
Description: 7str. to
19str. tinned copper, .016" wall 80°C PVC. STD.
P-U: 100',1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
1420/24 | MW-C-24(7)A | 24-7/32 | .016" | 1000 | .057" |
1420/22 | MW-C-22(7)A | 22-7/30 | .016" | 1000 | .064" |
1420/20 | MW-C-20(7)A | 20-7/28 | .016" | 1000 | .072" |
1420/18 | MW-C-18(16)A | 18-16/30 | .016" | 1000 | .083" |
1420/16 | MW-C-16(19)A | 16-19/29 | .016" | 1000 | .096" |
1420/14 | MW-C-14(19)A | 14-19/27 | .016" | 1000 | .110" |
1420/12 | MW-C-12(19)A | 12-19/25 | .016" | 1000 | .130" |
RoHS compliant wires are available to order.
TYPE
HW-C--uncovered OPER. VOLT.:
2500V OPER. TEMP: -40°C to +80°C
Description: Stranded
tinned copper conductor, .031" to .045" wall 80°C
PVC. STD. P-U: 100',1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
|
1430/24 | HW-C-24(7)A | 24-7/32 | .031" | 2500 | .085" | 1430/12 | HW-C-12(65)A | 65/30 | .045" | 2500 | .186" | |
1430/22 | HW-C-22(7)A | 22-7/30 | .031" | 2500 | .094" | 1430/10 | HW-C-10(105)A | 105/30 | .045" | 2500 | .210" | |
1430/20 | HW-C-20(10)A | 20-10/28 | .031" | 2500 | .101" | 1430/8 | HW-C-8(133)A | 133/29 | .045" | 2500 | .270" | |
1430/18 | HW-C-18(16)A | 18-16/30 | .031" | 2500 | .112" | 1430/6 | HW-C-6(133)A | 133/27 | .045" | 2500 | .310" | |
1430/16 | HW-C-16(26)A | 16-26/30 | .031" | 2500 | .124" | 1430/4 | HW-C-4(133)A | 133/25 | .045" | 2500 | .365" | |
1430/14 | HW-C-14(41)A | 14-41/30 | .031" | 2500 | .142" | 1430/2 | HW-C-2(665)A | 665/30 | .060" | 2500 | .460" |
RoHS compliant wires are available to order.
TYPE
MW-C--uncovered. OPER. VOLT.:
1000V OPER. TEMP: -40°C to +80°C
Description: Solid
tinned copper conductor, .016" wall 80°C PVC.
STD. P-U: 1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
1420/24S | MW-C-24(1)A | 24(1) | .016" | 1000 | .052" |
1420/22S | MW-C-22(1)A | 22(1) | .016" | 1000 | .057" |
1420/20S | MW-C-20(1)A | 20(1) | .016" | 1000 | .064" |
1420/18S | MW-C-18(1)A | 18(1) | .016" | 1000 | .072" |
RoHS compliant wires are available to order.
TYPE MW-C--Nylon
covered OPER. VOLT.:
1000V OPER. TEMP: -40°C to +80°C
Description: 7str. to
105str. tinned copper, .016" wall 80°C PVC plus a .002" to
.005" clear Nylon jacket.
STD. P-U: 1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Nylon Jack. |
Oper. Volt. |
Nom. O. D. |
1420/24N | MW-C-24(7)B | 24-7/32 | .016" | .002" | 1000 | .063" |
1420/22N | MW-C-22(7)B | 22-7/30 | .016" | .003" | 1000 | .070" |
1420/20N | MW-C-20(7)B | 20-7/28 | .016" | .003" | 1000 | .078" |
1420/18N | MW-C-18(16)B | 18-16/30 | .016" | .003" | 1000 | .089" |
1420/16N | MW-C-16(19)B | 16-19/29 | .016" | .004" | 1000 | .104" |
1420/14N | MW-C-14(19)B | 14-19/27 | .016" | .004" | 1000 | .118" |
1420/12N | MW-C-12(19)B | 12-19/25 | .016" | .004" | 1000 | .140" |
1420/10N | MW-C-10(105)B | 10-105/30 | .016" | .005" | 1000 | .168" |
RoHS compliant wires are available to order.
TYPE MW-C--Glass braided
jacket. OPER. VOLT.:
1000V OPER. TEMP: -40°C to +80°C
Description: Stranded
tinned copper conductor, .016" wall of 80°C PVC plus a White
glass
braided jacket.
STD. Color:
White
STD.
P-U: 1000'
Brim No. |
MIL/Type Designation |
AWG/ Strand. |
Nom. Wall |
Glass Jack. |
Oper. Volt. |
Nom. O. D. |
1420/22B | MW-C-22(7)C | 22-7/30 | .016" | .005" | 1000 | .075" |
1420/20B | MW-C-20(7)C | 20-7/28 | .016" | .006" | 1000 | .084" |
1420/18B | MW-C-18(16)C | 18-16/30 | .016" | .006" | 1000 | .095" |
1420/16B | MW-C-16(26)C | 16-26/30 | .016" | .006" | 1000 | .108" |
1420/14B | MW-C-14(41)C | 14-41/30 | .016" | .006" | 1000 | .122" |
1420/12B | MW-C-12(65)C | 12-65/30 | .016" | .006" | 1000 | .144" |
RoHS compliant wires are available to order.
DESCRIPTION: 7str.
or 19str. tinned copper, .009" semi-rigid PVC
insulation. Suitable for
business machines &
electronic components. OPER. VOLT.:
300V OPER. TEMP: -10°C to +80°C
STD. P-U: 100',1000'
Brim
No. |
AWG/
Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
1480/26 | 26-7/34 | .009" | 300 | .035" |
1480/24 | 24-7/32 | .009" | 300 | .041" |
1480/22 | 22-7/30 | .009" | 300 | .047" |
1480/20 | 20-7/28 | .009" | 300 | .055" |
1480/18 | 18-7/26 | .009" | 300 | .065" |
1480/16 | 16-19/29 | .009" | 300 | .075" |
RoHS compliant wires are available to order.
DESCRIPTION: .016"
wall of PVC over a 7 strands to 19 strands tinned copper
conductor.
OPER. VOLT.:
300V OPER. TEMP: -40°C to
+80°C
STD.
P-U: 100',1000'
Brim No. |
AWG- Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
1470/24 | 24-7/32 | .016" | 300 | .058" |
1470/22 | 22-7/30 | .016" | 300 | .064" |
1470/20 | 20-7/28 | .016" | 300 | .072" |
1470/18 | 18-16/30 | .016" | 300 | .082" |
1470/16 | 16-19/29 | .016" | 300 | .091" |
UL 1569 FOR 105°C
APPLICATIONS IS AVAILABLE TO ORDER.
RoHS compliant wires are available to order.
DESCRIPTION: .016"
wall of PVC plus a clear Nylon jacket over a 7 strands to 19
strands tinned
copper
conductor. OPER. VOLT.:
300V OPER. TEMP: -40°C to
+90°C STD. P-U:
100',1000'
Brim
No. |
AWG/
Strand. |
Nom. Wall |
Nom. Jack. |
Oper. Volt. |
Nom. O. D. |
1470/24N | 24-7/32 | .016" | .002" | 300 | .061" |
1470/22N | 22-7/30 | .016" | .003" | 300 | .069" |
1470/20N | 20-7/28 | .016" | .003" | 300 | .077" |
1470/18N | 18-16/30 | .016" | .003" | 300 | .087" |
1470/16N | 16-19/29 | .016" | .004" | 300 | .098" |
RoHS compliant wires are available to order.
DESCRIPTION: 7
strands to 105 strands tinned copper conductor, with a .031"
wall of 105°C PVC.
OPER. VOLT.:
600V OPER. TEMP: -40°C to +105°C.
Brim
No. |
AWG/ Strand. |
Nom. Wall |
Oper. Volt. |
Nom. O. D. |
1475/24 | 24- 7/32 | .031" | 600 | .085" |
1475/22 | 22- 7/30 | .031" | 600 | .091" |
1475/20 | 20- 7/28 | .031" | 600 | .099" |
1475/18 | 18-16/30 | .031" | 600 | .112" |
1475/16 | 16-26/30 | .031" | 600 | .122" |
1475/14 | 14-41/30 | .031" | 600 | .142" |
1475/12 | 12-65/30 | .031" | 600 | .160" |
1475/10 | 10-105/30 | .031" | 600 | .192" |
*CSA TR-32 IS AVAILABLE TO
ORDER.
RoHS compliant wires are available to order.